pH and Electrochemistry
Filtered Search Results
Thermo Scientific™ Orion™ ROSS Ultra™ Refillable Epoxy Bodied Combination pH Electrode
Confidently maneuver and measure in the field or on the plant floor with Orion refillable epoxy body electrodes.
Thermo Scientific™ Orion Star™ A221 Portable pH Meter
Reliably measure pH, mV, ORP and temperature with our portable pH meter for advanced field analysis and printer or computer interfacing.
Thermo Scientific™ Orion™ Pro Star PC215 pH/Ion and Conductivity Bench Meter with Stand PROMO
Designed to provide accurate and reliable pH, ORP, ion concentration, conductivity, TDS, salinity, resistivity and temperature analysis, the Thermo Scientific™ Orion™ Pro Star PC215 bench meter is well suited for laboratories that desire a modern meter with advance performance.
Thermo Scientific™ Orion™ Versa Star Pro™ Conductivity Benchtop Meter
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Get high accuracy, premium performance and ultimate flexibility with this conductivity benchtop meter designed for conductivity, total dissolved solids (TDS), salinity, resistivity and temperature.
| Power Rating | DC input: 9VDC, 1A |
|---|---|
| Salinity Measurement Modes | Practical salinity (psu) or natural sea water (ppt) |
| Range (Resistivity) | 2 ohm to 100.0 megohm |
| Memory | Non-volatile memory preserves data log, calibration log and meter settings |
| Languages | English, Spanish, French, Italian, German, Chinese, Portuguese and Korean |
| Measurement Modes | Conductivity,TDS,Salinity,Resistivity with Temperature |
| Power Supply | Universal AC adapter (included) |
| Data Management Details | Transfer single, range or all data points to printer or computer |
| Display Type | Color Graphic LCD with User-customizable Options |
| Data Points | 2000 with Date and Time Stamp |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| Resolution (Conductivity) | 0.001 μS minimum, auto ranging up to 4 significant digits |
| Range (Conductivity) | 0.001 μS/cm to 3000 mS/cm |
| Log Function Type | Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with |
| Relative Humidity Range | 5 to 85%, non-condensing |
| Dimensions (L x W x H) | 28 x 24 x 10 cm (11 x 9.5 x 3.9 in.), modules add ≤ 2 cm (0.8 in.) L & H |
| Accuracy (TDS) | 0.5% of reading ±1 digit |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| Keypad | Numeric with menu-specific function keys and dual purpose scroll/shortcut keys |
| Outputs | USB (2), RS232 |
| Backlight Option | Yes |
| Compatible Probes | 2-cell or 4-cell conductivity sensors with built-in temperature |
| Methods | 10 per channel |
| Cell Constant | 0.001 to 199.9 cm-1 |
| Temperature (Metric) Reference | 5, 10, 15, 20, 25°C |
| Channels | 4 (Customizable with modules) |
| TDS Factor Range | Linear (0.02 to 9.99) |
| Range (Salinity) | 0.06 to 80.00 psu, 0.05 to 42.00 ppt |
| Temperature Compensation | Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off wit |
| Accuracy (Salinity) | 0.5% of reading ±1 digit |
| Resolution (Salinity) | 0.01 psu or 0.01 ppt minimum, auto ranging |
| Accuracy (Conductivity) | 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS |
| Inputs | 8 pin MiniDIN (conductivity sensor with built-in temperature), two stirrer inputs (stirrer probe) |
| Accuracy (Temperature) | ±0.1°C |
| Weight (Metric) | 1.2 kg, modules add 0.2 kg each |
| Calibration Points (Conductivity) | 6 |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Resolution (Resistivity) | 1 ohm or 0.1 megohm, auto ranging |
| Accuracy (Resistivity) | 0.5% of reading ±1 digit |
| AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR) |
| Resolution (TDS) | 0.001 ppm minimum, auto ranging up to 4 significant digits |
| Calibration | Conductivity with calibration editing option and temperature |
| Alarm Output | Set point alarm, high/low limit alarm, calibration due alarm |
| IP Rating | IP54 |
| Weight (English) | 2.5 lb., modules add 0.5 lb. each |
| Resolution (Temperature) | 0.1°C (0.1°F) |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | -5°C to +105°C |
METTLER TOLEDO™ InLab™ Solids pH Electrodes
A low maintenance glass pH electrode with an integrated temperature probe featuring a clog-free, open junction that eliminates the risk of protein fouling. Its spear shaped tip is designed for piercing solid and semi-solid food samples (IP67 rated).
| pH Range | 1 to 11 |
|---|---|
| Membrane | LoT Glass |
| Material | Glass |
| Junction | Open |
| Temperature (Metric) Operating | 0°C to 80°C |
| Internal Reference | ARGENTHAL |
Thermo Scientific™ Orion™ 2-Cell Conductivity Electrodes
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Achieve accurate measurements from ultrapure water, sea water, and more with these versatile 2-cell conductivity electrodes, available in a variety of materials and measurement ranges.
| Type | 2-Electrode Conductivity Cells |
|---|
Thermo Scientific™ Orion Star™ A221 Portable pH Meter PROMO
Reliably measure pH, mV, ORP and temperature with our portable pH meter for advanced field analysis and printer or computer interfacing.
Mettler Toledo™ Protective Cover for S230 SevenCompact Conductivity Meters
Accessory for S230 SevenCompact Conductivity Meters.
Thermo Scientific™ Orion™ Versa Star Pro™ pH/Conductivity Multiparameter Benchtop Meter
Get premium performance and flexibility with our benchtop meter with pH and conductivity modules for simultaneous pH, conductivity, and temperature.
| Power Rating | DC input: 9VDC, 1A |
|---|---|
| Salinity Measurement Modes | Practical salinity (psu) or natural sea water (ppt) |
| Range (Resistivity) | 2 ohm to 100.0 meg-ohm |
| Memory | Non-volatile memory preserves data log, calibration log and meter settings |
| Resolution (pH) | 0.1/0.01/0.001 |
| Languages | English, Spanish, French, Italian, German, Chinese, Portuguese and Korean |
| Measurement Modes | pH,mV,Relative mV,TDS,ORP with Temperature,Salinity,Conductivity,Resistivity with Temperature |
| Power Supply | Universal AC adapter (included) |
| Data Management Details | Transfer single, range or all data points to printer or computer |
| Display Type | Color graphic LCD with user-customizable options |
| Resolution (mV) | 0.1mV |
| Data Points | 2000 with Date and Time Stamp |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Warranty | 3 year meter and module warranty |
| Temperature Accuracy | ±0.1°C |
| Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| Resolution (Conductivity) | 0.001 μS minimum, auto ranging up to 4 significant digits |
| Range (Conductivity) | 0.001 μS/cm to 3000 mS/cm |
| Log Function Type | Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Dimensions (L x W x H) | 28cm x 24cm x 10cm (11 in. x 9.5 in. x 3.9 in.), modules add ≤ 2cm (0.8 in.) L & H |
| Accuracy (TDS) | 0.5% of reading ±1 digit |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| Keypad | Numeric with menu-specific function keys and dual purpose scroll/shortcut keys |
| Outputs | USB (2), RS232 |
| Temperature Range (English) | 22.0°F to 221.0° F |
| Range (Relative mV) | ±2000.0 mV |
| Calibration Points (pH) | 1 to 6 |
| Backlight Option | Yes |
| Range (mV) | ±2000.0 mV |
| Range (ORP) | ±2000.0 mV |
| Methods | 10 per channel |
| Cell Constant | 0.001 to 199.9cm-1 |
| Temperature (Metric) Reference | 5, 10, 15, 20, 25°C |
| Range (pH) | -2 to 20 |
| TDS Factor Range | Linear (0.02 to 9.99) |
| Channels | 4 (Customizable with modules) |
| Accuracy (pH) | ±0.002 |
| Range (Salinity) | 0.06 to 80.00 psu, 0.05 to 42.00 ppt |
| Temperature Compensation | Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off |
| Accuracy (Salinity) | 0.5% of reading ±1 digit |
| Resolution (Salinity) | 0.01 psu or 0.01 ppt minimum, auto ranging |
| Accuracy (Conductivity) | 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS |
| Inputs | BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 8 pin MiniDIN (conductivity sensor with built-in temperature), two stirrer inputs (stirrer probe) |
| Weight (Metric) | 1.2 kg, modules add 0.2 kg each |
| Calibration Points (Conductivity) | Up to 6 |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Resolution (Resistivity) | 1 ohm or 0.1 meg-ohm, auto ranging |
| Isopotential Point | 7.000pH (adjustable) |
| Accuracy (Resistivity) | 0.5% of reading ±1 digit |
| AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR) |
| Range (TDS) | 0.001 ppm to 200.0 ppt |
| Resolution (TDS) | 0.001 ppm minimum, auto ranging up to 4 significant digits |
| Calibration | pH with calibration editing option, relative mV (RmV), ORP, conductivity with calibration editing op |
| Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
| Alarm Output | Set point alarm, high/low limit alarm, calibration due alarm |
| IP Rating | IP54 |
| Weight (English) | 2.5 lb., modules add 0.5 lb. each |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | -5.0°C to +105.0°C |
| Temperature Resolution | 0.1°C, 0.1°F |
Thermo Scientific™ Orion™ Single Junction Epoxy Bodied pH/ATC Triode™
Accurately measure pH and temperature together in just one electrode, with a built-in temperature sensor.
| Diameter (English) Body | 0.47 in. |
|---|---|
| Description | pH/ATC Triode |
| Length (Metric) | 120 mm |
| Temperature (English) Operating | 32°F to 176°F |
| pH Range | 0 to 14 |
| Length (English) | 4.7 in. |
| Diameter (Metric) Cap | 16 mm |
| Junction | Wick |
| Material | Epoxy |
| Diameter (Metric) Body | 12 mm |
| For Use With (Application) | The Thermo Scientific Orion 9107BN Triode 3-in-1 pH/automatic temperature compensation probe has a low maintenance gel filled electrode with built-in ATC.For field or plant use. |
| Temperature (Metric) Operating | 0°C to 80°C |
| Reference Type | Ag/AgCl |
Thermo Scientific™ Orion Lab Star DO Dissolved Oxygen Bench Meters
Orion Lab Star DO113 dissolved oxygen bench meters measure DO as % saturation or concentration with temperature, feature large backlit display for easy viewability, and offer small footprint to save bench space. This DO meter is ideal for simplified, budget-friendly lab testing and data recording.
| Temperature (Metric) Range | -5.0°C to +105.0°C |
|---|---|
| Resolution (Polarographic DO) | 0.1, 1 % saturation; 0.01, 0.1 mg/L or ppm |
| Pressure Range | 400.0 to 850.0 mmHg; 0.533 to 1.133 bar |
| Memory | Non-volatile |
| Measurement Modes | Dissolved Oxygen (% Saturation with Temperature),Dissolved Oxygen (mg/L with Temperature),Dissolved Oxygen (ppm with Temperature) |
| Data Management Details | Continuous, Auto-Read and Timed read modes |
| Display Type | 5 in. backlit LCD |
| Data Points | 500 Sets with Date and Time Stamp |
| Calibration Modes | 100 % saturation, 0 % saturation, custom concentration value |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Accuracy (Temperature) | ±0.3°C, ±0.5°F |
| Weight (Metric) | 700 grams |
| Warranty | 3 year meter warranty |
| AC Adapter | Universal 100-240 V 50/60 Hz power supply with twist-and-lock meter connection and interchangeable wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
| Sensor Types | Polarographic |
| Percent Saturation Range Polarographic DO | 0.0 to 300.0 % saturation |
| Log Function Type | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
| Relative Humidity Range | 5 to 85%, non-condensing |
| Alarm Output | Calibration reminder alarm |
| Dimensions (L x W x H) | 187.2 x 155.2 x 61.7 mm, 7.37 x 6.11 x 2.43 in. |
| IP Rating | IP54 |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| Outputs | Computer or printer (STARA-106) |
| Backlight Option | Yes |
| Weight (English) | 1.54 lb. |
| Resolution (Temperature) | 0.1°C, 0.1°F |
| Range (Polarographic DO) | 0.0 to 300.0 % saturation; 0.00 to 30.0 mg/L or ppm |
BUCHI pH Electrode Gel
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
For use with KjelMaster K-375.
Thermo Scientific™ Elite pH Spear Pocket Testers and Replacement Sensors
Flexible on-the-go pH testing using durable Elite spear pocket testers with replaceable sensors for a variety of applications include food, beverage, agriculture and more!
| Temperature Accuracy | Manual input |
|---|---|
| Temperature Range (English) | 32.0°F to 140.0°F |
| Resolution (pH) | 0.01 |
| Measurement Modes | pH |
| Range (pH) | -1 to 15 |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | 0.0°C to 60.0°C |
| Accuracy (pH) | ±0.02 |
| Temperature Resolution | 0.1°C, 0.1°F |
Thermo Scientific™ Orion™ AUTO-STIR™ Polarographic Dissolved Oxygen Electrode
Accurately and conveniently conduct dissolved oxygen measurements.
Thermo Scientific™ Orion™ ROSS Ultra™ Glass Triode™ pH/ATC Combination Electrode, With miniDIN connector, for use with Orion Star meters, With miniDIN connector; for use with Orion Star meters PROMO
Combine a rapid temperature response with stability when using Thermo Scientific™ Orion™ ROSS Ultra™ Glass Triode™ pH/ATC Combination Electrodes.